LZQ TOOL CO., LTD. +86-021-50327060
LZQ TOOL CO., LTD. zq@lzqtech.com
LZQ Tools

Ratchet Wrench

Ratchet Wrench

Description

Application domain: implant
Material:  Ultra high anti-rust & high-hardness stainless steel, high anti-rust stainless steel
Type:ratchet, torque
LZQ is an OEM factory for all kinds of dental implant wrenches, such as Wrench P53, Key P47, Parallel Pin P37, Screwdriver P79, Tap P152, Lance Drill P172, etc. We can also produce a whole kit of tools for customers' surgical cases.

Product Details

Fixed and Adjustable dental ratchet wrench, LZQ has ratchet size 4mm and 6.35mm connection in stock now for use with the different surgical instruments. We can also customize wrench of any shape and size. Adjustable torque wrench could be adjustable to different values: 15;35;50 Ncm and 70 Ncm. We can also make wrench of any torque value according to your requirement, compatible with hex screwdriver, Torx screwdriver, or adapter of any size and shape. Separable, autoclavable(134°C), stainless steel. Designed to place both implants& abutment with the distinct torque settings scale which adjusts the torque level. Sample twist of the handle tip adjusts the torque level We can also mark different Newton sign on torque wrench according to your requirement. Allows you to know with precision the insertion torque of the implant in the maxillary bone.  Any shape of personalized handle and size can be customized

Gentle remarks: The torque, indicated for each screw or abutment avoid micro-movements and/or bacterial infiltrations. It is very important not to exceed the torque to avoid a possible elongation and/or deformation of the elements to be tightened.

The relevance of important implant balance decreases steadily with regrowth of bone tissue around the implant in the first weeks after surgery, main to secondary stability. Secondary balance is one of a kind from the initial stabilization, due to the fact it effects from the ongoing process of bone regrowth into the implant (osseointegration). When this restoration manner is complete, the preliminary mechanical steadiness turns into biological stability. Primary balance is indispensable to implantation success until bone regrowth maximizes mechanical and organic help of the implant. Regrowth usually occurs in the course of the 3–4 weeks after implantation. Insufficient fundamental stability, or excessive initial implant mobility, can lead to failure.

Multi-picture display

Similar Products

Leave a Message

we will contact you within 24 hours.

Contact us